ADA Guidelines for Aluminum Ramps

Slope, landings, handrails, and access requirements.

An aluminum ramp can be part of an accessible entrance when its layout and installation meet the applicable requirements. Material alone does not establish ADA compliance.

Ramp Dimensions at a Glance

FeatureGeneral ADA requirement
Running slope1:12 maximum (8.33%); a gentler slope is preferable where feasible.
Cross slope1:48 maximum.
Clear width36 inches minimum, measured between handrails where provided.
Rise per run30 inches maximum before a landing.
LandingsAt top and bottom of each run; at least 60 inches long and as wide as the run. Direction changes need at least 60 by 60 inches clear.

Understanding 1:12 Slope

For each inch of vertical rise, allow at least 12 inches of horizontal run. A 24-inch entry height therefore needs at least 24 feet of horizontal ramp run at 1:12, plus landings. Ramp run is the horizontal distance, not the sloped surface length.

Handrails and Edge Protection

Ramps with a rise greater than 6 inches generally require handrails on both sides. Gripping surfaces must be 34–38 inches above the ramp, continuous along the run, and meet clearance and grip requirements. Ramp handrail extensions generally continue horizontally at least 12 inches past the top and bottom of the run, with required returns; exceptions apply, including continuous inside rails at switchbacks.

Edge protection is generally required along runs and landings. Compliant options include an extended surface or a curb or barrier meeting the standard; a handrail alone does not necessarily provide edge protection.

Surfaces, Drainage, and Door Access

Ramp and landing surfaces must be firm, stable, and slip-resistant. Outdoor landings must prevent water accumulation. An aluminum ramp's surface, transitions, and installation need to support these requirements. Keep required landing space and door maneuvering clearances unobstructed.

Applying the Guidelines to Your Property

This overview summarizes common requirements, not every provision or exception. Confirm which accessibility standards and local building requirements apply to your property, and follow the ramp manufacturer's installation instructions. Final compliance depends on the entire accessible route and installed configuration.

Official ADA References